BLE 智能取电开关 — 蓝牙 + WiFi 酒店取电控制
BLE 智能取电开关集成蓝牙 LE 与 WiFi,支持 App 房间取电控制。兼容客人手机或 MIFARE 卡,上云记录用电日志,削减 25–40% 客房能耗。智能节能开关与 WiFi 节能开关,助力智慧酒店。
查看详情更适合使用 中文?我们会保留当前页面上下文,只在您确认后切换。
We build hotel key card switches and room energy saving switches in-house — universal card, RFID/MIFARE, TTLOCK compatible, BLE+WiFi, and PIR/mmWave occupancy models share the same 30A relay platform. Every switch cuts 25–40% of guest-room electricity with no rewiring.
Hotel key card switches and occupancy sensor switches that cut 25–40% of guest-room electricity — universal, RFID/MIFARE, TTLOCK compatible, BLE smart, and PIR/mmWave models on a shared 30A relay platform.
BLE 智能取电开关集成蓝牙 LE 与 WiFi,支持 App 房间取电控制。兼容客人手机或 MIFARE 卡,上云记录用电日志,削减 25–40% 客房能耗。智能节能开关与 WiFi 节能开关,助力智慧酒店。
查看详情
酒店取电开关,经典插卡取电、拔卡延时断电控制。16A 大负载驱动接触器控制空调热水器。220V 交流电。CE RoHS 认证。OEM/ODM 供应商。
查看详情
酒店取电开关插卡通电、拔卡延时断电,联动空调停止空房浪费。220V AC,10A-16A,RS485或干接点。CE RoHS。OEM/ODM供应商。
查看详情
酒店取电开关实现客房电源智能控制。RFID/IC卡识别,插卡取电,拔卡延时断电。220V交流,10A-16A,RS485或干接点。CE RoHS认证。OEM/ODM源头供应商。
查看详情Our hotel key card switches and occupancy switches share one 30A relay platform — so a single supplier covers universal, RFID, TTLOCK, BLE, and occupancy control across every room type, with consistent quality and delivery.
200,000 switches per month on a shared 30A relay platform, with controlled capacity for repeat hotel and distributor orders.
Every switch passes in-process inspection, first-article report, and final outgoing inspection. CE and RoHS certified.
Switches shipped FOB Shenzhen, CIF, or DDP to 6 export markets (US, Germany, UK, Japan, UAE, Vietnam) with full CE/RoHS documentation.
Universal UID, room-bound RFID/MIFARE, TTLOCK sector-key, BLE+WiFi, and PIR/mmWave occupancy — one platform covering every hotel card and control scenario.
A hotel key card switch is the wall device that turns a guest room's power on when a card is inserted and off when it is removed. Guests cannot leave the AC, lights, and sockets running after checkout — so the room energy saving switch typically cuts 25–40% of guest-room electricity with no network, no app, and no rewiring.
For a retrofit or a budget property, a universal card switch reads any MIFARE / Temic UID, so you deploy across hundreds of rooms using the cards you already have. For ecosystem-locked hotels, a TTLOCK compatible or RFID room-bound switch stops card-sharing between rooms. And for card-free rooms, a PIR / mmWave occupancy switch powers the room by presence instead of by card.
One 30A relay platform covers universal, RFID, TTLOCK, BLE smart, and occupancy control — so a single supplier handles every room type in your hotel, serviced apartment, or dormitory project.
Five hotel energy saving switches — pick the card technology and control mode that match your lock system and room types. All five share the same 30A relay platform, 86×86 panel, and 15-second delay-off.
10+ years building room energy saving switches, 6+ export markets, 24h response, and full OEM/ODM support. Every switch is CE and RoHS certified.
Common questions from hotel and procurement buyers evaluating our key card and occupancy energy saving switches — card types, universal vs encrypted, TTLOCK, occupancy control, and OEM/ODM terms.
A hotel key card switch is the wall device that powers a guest room when a card is inserted and cuts power when the card is removed. It typically saves 25–40% of guest-room electricity because guests cannot leave the AC running after checkout. Our guide to hotel key card switches covers types, wiring, and how to specify one.
Our universal switch reads any 125kHz Temic or 13.56MHz MIFARE card by UID only. Room-bound RFID switches accept a specific MIFARE/Temic card written for that room, and TTLOCK compatible switches use TTLOCK/TTHotel sector-key auth. See our hotel key card types explainer for the full M1 / MIFARE / Temic breakdown.
A universal switch works with any card (no lock-in) and is best for retrofits and budget properties. An encrypted or room-bound switch (RFID/TTLOCK) stops guests moving a card from one room to another to keep both powered, which suits branded and chain hotels. Our universal vs encrypted comparison walks through the security and card-sharing trade-offs.
Yes. Our TTLOCK compatible energy switch powers the room only for the correct room card and only inside the check-in window — auto power-off at checkout, no manual reset. It works with TTLOCK / TTHotel MIFARE cards via sector-key auth on the shared 30A platform. Read the TTLOCK integration guide for ecosystem details.
A hotel occupancy sensor switch powers the room by presence, not by card — using PIR or mmWave detection, with optional door-contact linkage. It is ideal for card-free rooms, staff areas, and bathrooms where a card is inconvenient. See our PIR vs mmWave occupancy switch comparison to pick the right detection mode.
We are the OEM/ODM manufacturer — every switch is designed and built in-house at our Shenzhen facility on a shared 30A relay platform. You buy direct from the factory, with full support for custom branding, packaging, and card-frequency matching for hotel or distributor rollouts. See our hotel energy management system solution for a real-world deployment, or contact us for sampling (7-10 days) and mass production (20-30 days).
Send your room voltage, card system, and target volume — we will respond within 24 business hours with a sample plan, quote, or next-step recommendation.
在表单附近明确说明支持内容和回复节奏,让客户知道应该提交什么信息,以及会收到怎样的反馈。
Your details are used only to prepare your quote — never sold or shared with third parties.
Room B1011, Niulanqian Mansion, Longhua District, Shenzhen, Guangdong, 518109, China
周一至周五: 9:00 - 18:00
周六周日: 休息
时区: Asia/Shanghai (UTC+8)
响应: Within 24 business hours
在表单附近明确说明支持内容和回复节奏,让客户知道应该提交什么信息,以及会收到怎样的反馈。
无线与有线酒店取电开关对比:布线复杂度、改造便利性、可靠性、供电方式、成本、延迟与覆盖。如何为您的项目选择合适的开关。
RFID 与 IC 酒店取电开关:125kHz 仅 UID 的 RFID 邻近卡 vs 13.56MHz MIFARE IC 智能卡。对比读取距离、安全性、加密、成本、兼容性及选择建议。
酒店取电开关接线图指引:进线端、继电器线圈、接触器、接线端子、负载回路,助力 180-250V 客房安全安装。
酒店取电开关与人体传感器的实用对比,涵盖供电控制方式、节能逻辑、响应速度、误触发场景、成本及组合应用场景。